THIS PROCEDURE WILL HELP YOU TURN ANY ELECTRICAL PANEL METER INTO A SENSITIVE BALANCE CAPABLE OF RESOLUTION BELOW 1 MILLIGRAM. |
|
A DIGITAL BALANCE HAS USES IN ALMOST EVERY INDUSTRY, FROM CHEMISTRY, TO PHARMACEUTICALS, TO COMPOSITE MATERIALS. DIGITAL BALANCES HAVE PLUMMETED IN COST IN RECENT YEARS, AND 10 OR 5 MILLIGRAM UNITS CAN BE HAD ON EBAY FOR LESS THAN 20 DOLLARS. SCALES WITH MILLIGRAM OR LESS RESOLUTION, HOWEVER, ARE STILL VERY EXPENSIVE, WITH LARGE UNITS INTO THE THOUSANDS OF DOLLARS. THIS PROCEDURE DESCRIBES A SIMPLE BALANCE CAPABLE OF RESOLUTION WELL BELOW 1 MILLIGRAM. IN SHORT, A PHOTO DIODE ADJUSTS THE CURRENT THROUGH A GALVANOMETER COIL IN ORDER TO PROVIDE A CONSTANT FORCE TO LIFT THE SAMPLE TO BE WEIGHED. GALVANOMETER HARDWARE IS AN EXCELLENT MATCH, SINCE THE COIL IS ALREADY WOUND, AND THE SAPPHIRE BEARINGS ARE EXTREMELY LOW FRICTION. |
|
|
MATERIALS |
-PANEL
METER -SOME PLEXIGLASS -IR EMITTER/PHOTOTRANSISTOR PAIR -MISC POT.S -100uH INDUCTOR -2N2222 TRANSISTOR -MISC RESISTORS, WIRE |
|
EQUIPMENT |
-SOLDERING
IRON -SUPERGLUE -DIGITAL MULTIMETER |
NOTE: SORRY ABOUT THIS, BUT I DESIGNED THIS BY TRIAL AND ERROR. AS SUCH, SOME OF THE PICTURES BELOW WERE TAKEN WHILE TRYING OUT COMPONENTS, OR COMPONENT VALUES THAT DIDN'T MAKE IT TO MY FINAL DESIGN. TRUST ONLY THE COMPONENTS AND VALUES IN THE SCHEMATIC. USE THE PICTURES ONLY FOR MECHANICAL DETAILS.
SCHEMATIC
ADJUSTMENT / USE
DEPENDING ON THE MATERIALS USED IN CONSTRUCTION, SOME ADJUSTMENT WILL BE NECESSARY. FOLLOW THE FOLLOWING STEPS TO BEGIN USING YOUR SCALE:
1. WITH NO WEIGHT ON THE PLATFORM, TURN ON THE BALANCE. THE NEEDLE MAY SWING TO THE TOP OF ITS TRAVEL; PUSH IT DOWN TO THE SENSOR REGION.
2. ADJUST THE SENSITIVITY POT UNTIL THE NEEDLE BALANCES. IT MAY BE JUST BARELY HELD IN POSITION AND WANT TO SWING UPWARDS, THAT'S OK. YOU WANT THIS POT ADJUSTED SO THAT VIBRATIONS DIE DOWN QUICKLY, BUT THE NEEDLE STAYS IN POSITION.
3. NOW ADJUST YOUR TARE POT UNTIL THE METER READS 0V.
4. ADD A TEST MASS OF KNOWN WEIGHT (PIECES OF MAGNET WIRE, ALUMINUM FOIL, ETC) AND ADJUST THE CALIBRATION POT UNTIL THE METER READ THE APPROPRIATE VOLTAGE.
READER QUESTIONS
NONE YET, BE THE FIRST!
GOT A QUESTION OF YOUR OWN? CLICK HERE TO ASK IT!